Configuration-list_byd-b-box-premium-lvs-4.0-4_00-kwh_2021_ENG

Openbaar kanaal / Magazyn energii

lista konfiguracji BYD LVS

Delen op sociale netwerken

Koppeling delen

Gebruik permanente koppeling om te delen via sociale media

Deel met een vriend

Alstublieft in te loggen voor het versturen van deze presentation per e-mail!

In uw website insluiten

Kies de startpagina

5. BYD Company Limited Battery - Box EU S ervice Partner Battery - Box AU Service Partner B YD US Service www.bydbatterybox.com EFT - Systems GmbH Alps Power Pty Ltd Global Sale s: batteryboxgrp@byd.com www.eft - systems.de www.alpspower.com.au bboxusservice@byd.com Global Service: bboxservice@byd.com info@eft - systems.de service@alpspower.com.au Version V1. 7 ; Update: 2021- 7 - 14 Note: - The Information in this document is subject to change without notice. Every effort has been made to make this document complete, accurate, and up- to -date. However, BYD may need to make some improvements under certain circumstances without advance notice. Please take the latest version of this document at our websites into account. [DE] Die Informationen in diesem Dokument können ohne vorherige Ankündigung geändert werden. Bitte berücksichtigen Sie die neueste Version dieses Dokuments auf unseren Websites. [ES] La información de este documento está sujeta a cambios sin previo aviso. Se ha hecho todo lo posible para que este documento sea completo, preciso y actualizado. Sin embargo, BYD puede necesitar realizar algunas mejoras bajo ciertas circunstancias sin previo aviso. Tenga en cuenta la última versión de este documento en nuestros sitios web. [IT] Le informazioni contenute in questo documento sono soggette a modifiche senza preavviso. È stato fatto ogni sforzo per rendere questo documento completo, accurato e aggiornato. Tuttavia, BYD potrebbe dover apportare alcuni miglioramenti in determinate circostanze senza preavviso. Si prega di prendere in considerazione l'ultima versione di questo documento sui nostri siti web. - In a single Tower system with 5 or 6 modules, the maximum load shall be no more than 12.8 kW [DE] In einem System mit nur einem Turm mit 5 oder 6 Modulen darf die maximale Last nicht mehr als 12,8 kW betragen. [ES] En un sistema de torre única con 5 o 6 módulos, la carga máxima no debe superar los 12,8 kW [IT] In un singolo sistema torre con 5 o 6 moduli, il carico massimo non deve essere superiore a 12,8 kW - Max. 64 modules can be connected in parallel. In parallel connection, each Tower shall be no more than 4 modules. [DE] max. 64 LVS Module in Parallelschaltung. In Parallelschaltung ist die maximale Modulanzahl je Turm 4 Module. [ES] Max. 64 módulos en conexión en paralelo. En conexión en paralelo, el número máximo de módulos por torre es de 4 módulos [IT] Max. 64 moduli in connessione parallela. In connessione parallela, il numero massimo di moduli per torre è di 4 moduli - ON -Grid with full backup power equals to OFF-Grid inrush power use. (section 4) [DE] ON -Grid mit voller Notstromversorgung entspricht den Einschaltströmen für OFF -Grid Anwendungen . (Sektion 4) [ES] ON-Grid con energía de respaldo completa equivale al uso de sistemas aislados para soportar picos de corriente máximos . (Sección 4) [IT] ON-Grid con piena potenza di backup è uguale all'uso in isola per potenza di pico ammisibile. (Sezione 4) - Configurations marked in grey are not released yet and are not allowed to be installed yet. Those configurations are planned and might be subject to change. [DE] Grau markierte Konfigurationen sind noch nicht freigegeben und dürfen noch nicht installiert werden. Diese Konfigurationen sind geplant und können sich ändern. [ES] Las configuraciones marcadas en gris aún no se publican y aún no se permite su instalación. Estas configuraciones están planificadas y pueden estar sujetas a cambios. [IT] Le configurazioni contrassegnate in grigio non sono ancora state rilasciate e non possono ancora essere installate. Tali configurazioni sono pianificate e potrebbero essere soggette a modifiche.

4. BYD Company Limited Battery - Box EU S ervice Partner Battery - Box AU Service Partner B YD US Service www.bydbatterybox.com EFT - Systems GmbH Alps Power Pty Ltd Global Sale s: batteryboxgrp@byd.com www.eft - systems.de www.alpspower.com.au bboxusservice@byd.com Global Service: bboxservice@byd.com info@eft - systems.de service@alpspower.com.au Version V1. 7 Update: 2021- 7 - 14 Note for Inrush Power: Each inverter has their inrush power for off grid applications . P lease make sure to consult the inverter manufacturer fo r the right value of correspondences. DE: Hinweis zu Einschaltströmen: Jeder Wechselrichter hat seine Einschaltströme für OFF-Grid Anwendungen. Bitte erkundigen Sie sich beim Hersteller des Wechselrichters nach dem richtigen Korrespondenzwert. ES: Nota sobre los picos de corriente: Cada inversor presenta unas características distintas con respecto a los picos de corriente permitidos así que es recomendable consultar con el fabricante de inversores que la información de esta tabla es la más reciente. IT: Note per Potenza di Pico Ammisibile: ogni inverter ha la sua Potenza di Pico Ammisibile per applicazioni in isola (Off-Grid). Consulta i valori correspondent dell’inverter usato. 4. Minimum Configuration List OFF Grid for Inrush Power Use DE : Minimale Konfiguration Off Grid , für hohe Einschaltströme / / ES : Configuración mínima para sistemas aislados para soportar picos de corriente máximos // IT : C onfigurazione minima per sistemi in isola per p otenza di p ico a mmisibile Compatible Inverter (1 - / 3 - phase) DE: Kompatibl er Wechselrichter ES: Inversores compatibles IT: Inverter compatibile Minimum Configuration for Single Phase DE: Minimale Konfiguration für eine Phase ES: Cantidad mínima de baterías para sistemas monofásicos aisladas con pico IT: Numero minimo di batter ie per sistemi monofase in isola con pico Minimum Configuration for Three Phase DE: Minimale Konfiguration für drei Phasen ES: Cantidad mínima de baterías para sistemas trifase aisladas con pico IT: Numero minimo di batterie per sistemi trifase in isola con pico LVS Module (remarks for inrush use) Tower (PDU) LVS Module (remarks for inrush use) Tower (PDU) SMA SI 4.4M ≥2 (5.5kw 3 seconds) ≥1 ≥8 (3*5.5kw 3 seconds) ≥2 SI 6.0 H /8.0H ≥4 (11kw 3 seconds) ≥1 ≥12 (3*11kw 3 seconds) ≥3 Battery firmware: BMU ≥ V1.19, BMS ≥ V1.8; Inverter firmware ≥ V 1.3.1.R. Please use below setting parameters for Sunny Island when w orking with LVS . Lower limit of deep discharge protection area prior shutdown <2% ; Minimum width of deep discharge protection area: ≥ 8% ; Area width for conserving battery state of charge: 3 - 5% . Victron Multiplus 48/3000/35 ≥2 (6kw 5 seconds) ≥1 ≥ 5 (3* 6kw 5 seconds) ≥2 Multiplus 48/5000/70 ≥3 (10kw 5 seconds) ≥1 ≥ 7 (3*10kw 5 seconds) ≥2 Multigrid 48/3000/35 ≥2 (6kw 5 seconds) ≥1 ≥ 5 (3*6kw 5 seconds) ≥2 Quattro 48/5000/70 - 100/100 ≥3 (10kw 5 seconds) ≥1 ≥ 7 (3*10kw 5 seconds) ≥2 Quattro 48/8000/110 - 100/100 ≥4 (16kw 5 seconds) ≥1 ≥12 (3*16kw 5 seconds) ≥3 Quattro 48/10000/140 - 100/100 ≥5 (20kw 5 seconds) ≥2 ≥1 5 (3*20kw 5 seconds) ≥4 Quattro 48/15000/200 - 100/100 ≥7 (25kw 5 seconds) ≥2 ≥ 18 (3*25kw 5 seconds) ≥6 Easysolar 48/ 3000/35 - 50 MPPT150/70 ≥2 (6kw 5 seconds) ≥1 ≥ 5 (3*6kw 5 seconds) ≥ 2 Easysolar 48/5000/70 - 100 MPPT150/100 ≥3 (10kw 5 seconds) ≥1 ≥ 7 (3*10kw 5 seconds) ≥2 Battery firmware: BMU ≥ V1.16, BMS ≥ V1.8; Inverter firmware ≥ V2.52 Selectronic SPMC480 - A U ≥2 (6kw 60 seconds) ≥1 ≥6 (3*6kw 60 seconds) ≥2 SPMC481 - AU ≥3 (12kw 30 seconds) ≥1 ≥9 (3*12kw 30 seconds) ≥3 SPMC482 - AU ≥5 (18kw 30 seconds) ≥2 ≥13 (3*18kw 30 seconds) ≥4 Battery firmware: BMU ≥ V1.17, BMS ≥ V1.8; Selectronic SP Link fir mware ≥ 14.20.x, SP Pro firmware ≥ V12.x Studer XTS1400 - 48 ≥1 ( 2.8kw 5 seconds ) ≥1 ≥ 2 ( 3*2.8kw 5 seconds ) ≥1 XTM2600 - 48 ≥ 2 ( 6.5kw 5 seconds ) ≥1 ≥ 5 ( 3*6.5kw 5 seconds ) ≥ 2 XTM4000 - 48 ≥ 3 ( 10.5kw 5 seconds ) ≥1 ≥ 8 ( 3*10.5kw 5 seconds ) ≥ 2 XTH60 00 - 48 ≥ 4 ( 15 kw 5 seconds ) ≥1 ≥1 1 ( 3*15 kw 5 seconds ) ≥ 3 XTH8000 - 48 ≥ 5 ( 21 kw 5 seconds ) ≥ 2 ≥1 5 ( 3*21 kw 5 seconds ) ≥ 4 VT - 65 ≥1 ≥1 ≥ 4 ≥1 VT - 80 / VS - 70 ≥ 2 ≥1 ≥ 4 ≥1 VS - 120 ≥ 3 ≥1 ≥ 8 ≥ 2 Battery firmware: BMU ≥ V1. 16 , BMS ≥ V1. 8; Inverter firmwa re ≥ R664 GoodWe ES Series ≥ 2 ≥1 / / GW3048 - EM ≥ 1 ≥1 / / GW3648 /5048 - EM ≥ 2 ≥1 / / SBP Series ≥ 2 ≥1 / / Battery firmware: BMU ≥ V1. 16 , BMS ≥ V1. 8; Inverter firmware ≥ ARM V11 Sungrow SH5K - 30 ≥ 1 ≥1 / / Battery firmwar e: BMU ≥ V1.16, BMS ≥ V1.8; Invert er firmware ≥ SH5K - 30_V01_V004 Schneider Conext XW Pro ≥ 4 ≥1 Battery firmware: BMU ≥ V1.20, BMS ≥ V1.10; Inverter firmware: Gateway FW :v1.14-BN465, XW FW: 1.10 / /

3. BYD Company Limited Battery - Box EU S ervice Partner Battery - Box AU Service Partner B YD US Service www.bydbatterybox.com EFT - Systems GmbH Alps Power Pty Ltd Global Sale s: batteryboxgrp@byd.com www.eft - systems.de www.alpspower.com.au bboxusservice@byd.com Global Service: bboxservice@byd.com info@eft - systems.de service@alpspower.com.au Version V1. 7 ; Update: 2021- 7 - 14 3. Minimum Configuration List OFF Grid Typical Use DE: Minimale Konfiguration Off Grid für den typischen Geb rauch// ES: Configuración mínima para sistemas aislados, uso convencional // IT: Configurazione minima per sistemi in isola, uso tipico Compatible Inverter (1 - / 3 - phase) DE: Kompatibler Wechselrichter ES: Inversores compatibles IT: Inverter compatibile M inimum Configuration for Single Phase DE: Minimale Konfiguration für eine Phase ES: Cantidad mínima de baterías para sistemas monofásicos aisladas IT: Numero minimo di batterie per sistemi monofase in isola Minimum Configuration for Three Phase DE: Mini male Konfiguration für drei Phasen ES: Cantidad mínima de baterías para sistemas trifase aisladas IT: Numero minimo di batterie per sistemi trifase in isola LVS Module Tower (PDU) LVS Module Tower (PDU) SMA SI 4.4M ≥ 2 ≥1 ≥ 8 ≥ 2 SI 6.0 H ≥ 4 ≥1 ≥ 12 ≥ 3 SI 8.0 H ≥ 4 ≥1 ≥ 12 ≥ 3 Battery firmware: BMU ≥ V1.19, BMS ≥ V1.8; Inverter firmware ≥ V 1.3.1.R. Please use below setting parameters for Sunny Island when working with LVS . Lower limit of deep discharge protection area prior shutdown <2% ; Minimum widt h of deep discharge protection area: ≥ 8% ; Area width for conserving battery state of charge: 3 - 5% . V ictron Multiplus 48/3000/35 ≥1 ≥1 ≥ 3 ≥1 Multiplus 48/5000/70 ≥ 2 ≥1 ≥ 5 ≥ 2 Multigrid 48/3000/35 ≥1 ≥1 ≥ 3 ≥1 Quattro 48/5000/70 - 100/100 ≥ 2 ≥1 ≥ 5 ≥ 2 Quattro 48 /8000/110 - 100/100 ≥3 ≥1 ≥9 ≥ 3 Quattro 48/10000/140 - 100/100 ≥ 4 ≥1 ≥1 1 ≥ 3 Quattro 48/15000/200 - 100/100 ≥ 6 ≥ 2 ≥1 6 ≥ 4 Easysolar 48/3000/35 - 50 MPPT150/70 ≥1 ≥1 ≥ 3 ≥1 Easysolar 48/5000/70 - 100 MPPT150/100 ≥ 2 ≥1 ≥ 5 ≥ 2 Battery firmware: BMU ≥ V1.16, BMS ≥ V1.8; Inverter firmware ≥ V2.52 Selectronic SPMC480 - AU ≥ 2 ≥1 ≥ 4 ≥1 SPMC481 - AU ≥ 2 ≥1 ≥ 5 ≥ 2 SPMC482 - AU ≥ 3 ≥1 ≥ 8 ≥2 Battery firmware: BMU ≥ V1.17, BMS ≥ V1.8; Selectronic SP Link firmware ≥ 14.20.x, SP Pro firmware ≥ V12.x Studer XTS1400 - 48 ≥1 ≥1 ≥ 2 ≥1 XTM2600 - 48 ≥1 ≥1 ≥ 3 ≥1 XTM4000 - 48 ≥ 2 ≥1 ≥ 4 ≥1 XTH6000 - 48 ≥ 2 ≥1 ≥ 6 ≥ 2 XTH8000 - 48 ≥ 3 ≥1 ≥ 8 ≥ 2 VT - 65 ≥1 ≥1 ≥1 ≥1 VT - 80 ≥ 2 ≥1 ≥ 2 ≥1 VS - 70 ≥ 2 ≥1 ≥ 2 ≥1 VS - 120 ≥ 3 ≥1 ≥ 3 ≥1 Battery firmware: BMU ≥ V1. 16 , BMS ≥ V1. 8; Inverter firmware ≥ R664 GoodWe ES Series / / / / GW3048 - EM / / / / GW3648 - EM / / / / GW5048 - EM / / / / SBP Series / / / / Battery firmware: BMU ≥ V1. 16 , BMS ≥ V1. 8; Inverter firmware ≥ ARM V11 Sungrow SH5K - 30 ≥1 ≥1 / / Battery firmware: BMU ≥ V1. 16 , BMS ≥ V 1. 8; Inverter firmware ≥ SH5K - 30_V01_V004 Schneider Conext XW Pro ≥ 4 ≥1 Battery firmware: BMU ≥ V1.20, BMS ≥ V1.10; Inverter firmware: Gateway FW :v1.14-BN465, XW FW: 1.10 / /

1. BYD Company Limited Battery - Box EU S ervice Partner Battery - Box AU Service Partner B YD US Service www.bydbatterybox.com EFT - Systems GmbH Alps Power Pty Ltd Global Sale s: batteryboxgrp@byd.com www.eft - systems.de www.alpspower.com.au bboxusservice@byd.com Global Service: bboxservice@byd.com info@eft - systems.de service@alpspower.com.au Version V1. 7 ; Update: 2021- 7 - 14 1. Minimum Configuration List O N Grid DE: Minimale Konfiguration ON Grid // ES: Configuración mínima para sistemas conectados a red // IT: Configurazione minima per sistemi in rete Compatible Inverter (1 - / 3 - phase) DE: Kompatibler Wechselric hter ES: Inversores compatibles IT: Inverter compatibile Minimum Configuration for Single Phase DE: Minimale Konfiguration für eine Phase ES: Cantidad mínima de baterías para sistemas monofásicos a red IT: Numero minimo di batterie per sistemi monofase in rete Minimum Configuration for Three Phase DE: Minimale Konfiguration für drei Phasen ES: Cantidad mínima de unidades para sistemas trifásicos a red IT: Numero minimo di batterie per sistemi tri fase in rete LVS Module Tower (PDU) LVS Module Tower (PD U) SMA SI 4.4M ≥1 ≥1 ≥4 ≥1 SI 6.0 H ≥ 2 ≥1 ≥6 ≥2 SI 8.0 H ≥ 3 ≥1 ≥ 8 ≥ 2 Battery firmware: BMU ≥ V1.19, BMS ≥ V1.8; Inverter firmware ≥ V 1.3.1.R. Please use below setting parameters for Sunny Island when working with LVS . Lower limit of deep discharge protection area pr ior shutdown <2% ; Minimum width of deep discharge protection area: ≥ 8% ; Area width for conserving battery state of charge: 3 - 5% . Victron Multiplus 48/3000/35 ≥1 ≥1 ≥1 ≥1 Multiplus 48/5000/70 ≥1 ≥1 ≥1 ≥1 Multigrid 48/3000/35 ≥1 ≥1 ≥1 ≥1 Quattro 48/50 00/70 - 100/100 ≥1 ≥1 ≥1 ≥1 Quattro 48/8000/110 - 100/100 ≥1 ≥1 ≥1 ≥1 Quattro 48/10000/140 - 100/100 ≥1 ≥1 ≥1 ≥1 Quattro 48/15000/200 - 100/100 ≥1 ≥1 ≥1 ≥1 Easysolar 48/3000/35 - 50 MPPT150/70 ≥1 ≥1 ≥1 ≥1 Easysolar 48/5000/70 - 100 MPPT150/100 ≥1 ≥1 ≥1 ≥1 Battery firmware: BMU ≥ V1.16, BMS ≥ V1.8; Inverter firmware ≥ V2.52 Selectronic SPMC480 - AU ≥1 ≥1 ≥3 ≥1 SPMC481 - AU ≥1 ≥1 ≥3 ≥1 SPMC482 - AU ≥ 2 ≥1 ≥6 ≥2 Battery firmware: BMU ≥ V1.17, BMS ≥ V1.8; Selectronic SP Link firmware ≥ 14.20.x, SP Pro firmwar e ≥ V12.x Studer XTS1400 - 48 ≥1 ≥1 ≥1 ≥1 XTM2600 - 48 / 4000 - 48 ≥1 ≥1 ≥1 ≥1 XTH6000 - 48 ≥1 ≥1 ≥1 ≥1 XTH8000 - 48 ≥1 ≥1 ≥1 ≥1 VT - 65 /80 ≥1 ≥1 ≥1 ≥1 VS - 70 /120 ≥1 ≥1 ≥1 ≥1 Battery firmware: BMU ≥ V1. 16 , BMS ≥ V1. 8 ; Inverter firmware ≥ R664 GoodWe ES / EM/B P/SBP Series ≥1 ≥1 / / Battery firmware: BMU ≥ V1. 16 , BMS ≥ V1. 8 ; Inverter firmware ≥ ARM V11 Sungrow SH5K - 30 ≥1 ≥1 / / Battery firmware: BMU ≥ V1. 16 , BMS ≥ V1. 8 ; Inverter firmware ≥ SH5K - 30_V01_V004 Solar E dge * SE 5 / 7 / 8 / 10 K - RWS / / ≥1 1 Batt ery firmware: BMU ≥ V1. 16 , BMS ≥ V1. 8 ; Inverter firmware ≥ 4.11 *Multiple towers are not supported S olis RHI - 3K / 3.6K - 48ES - 5G ≥ 1 ≥ 1 / / RHI - 4.6K / 5K / 6K - 48ES - 5G ≥ 2 ≥ 1 / / RAI - 3K - 48ES - 5G ≥ 1 ≥ 1 / / Battery firmware: BMU ≥ V1.19, BMS ≥ V1.08; Solis RHI (3 - 6K) - 48ES - 5G firmware ≥ V330022, RAI - 3K - 48ES - 5G ≥ V0B0009 Schneider Conext XW Pro ≥ 3 ≥1 Battery firmware: BMU ≥ V1.20, BMS ≥ V1.10; Inverter firmware: Gateway FW :v1.14-BN465, XW FW: 1.10 BYD BATTERY-BOX PREMIUM LVS MINIMUM CONFIGURATION LIST – V1. 7 / /

2. BYD Company Limited Battery - Box EU S ervice Partner Battery - Box AU Service Partner B YD US Service www.bydbatterybox.com EFT - Systems GmbH Alps Power Pty Ltd Global Sale s: batteryboxgrp@byd.com www.eft - systems.de www.alpspower.com.au bboxusservice@byd.com Global Service: bboxservice@byd.com info@eft - systems.de service@alpspower.com.au Version V1. 7 ; Update: 2021- 7 - 14 2. Minimum Configuration List O N Grid + Backup DE : Mini male Konfiguration für Notstrom / / ES : Configuración mínima para sistemas energía de emergencia / / IT : Configurazione minima per sistemi di alimentazione di emergenza Compatible Inverter (1 - / 3 - phase) DE: Kompatibler Wechselrichter ES: Inversores compatibles IT: Inverter compatibile Minimum Configuration for Single Phase DE: Minimale Konfiguration für eine Phase ES: Cantidad mínima de baterías para sistemas monofásic os a red con backup IT: Numero minimo di batterie per sistemi monofase in rete con backup Minimum Configuration for Three Phase DE: Minimale Konfiguration für drei Phasen ES: Cantidad mínima de baterías para sistemas trifase a red con backup IT: Numero m inimo di batterie per sistemi trifase in rete con backup LVS Module Tower (PDU) LVS Module Tower (PDU) SMA SI 4.4M ≥ 2 ≥1 ≥ 8 ≥ 2 SI 6.0 H ≥ 4 ≥1 ≥ 12 ≥ 3 SI 8.0 H ≥ 4 ≥1 ≥ 12 ≥ 3 Battery firmware: BMU ≥ V1.19, BMS ≥ V1.8; Inverter firmware ≥ V 1.3.1.R. Please use below setting parameters for Sunny Island when working with LVS . Lower limit of deep discharge protection area prior shutdown <2% ; Minimum width of deep discharge protection area: ≥ 8% ; Area width for conserving battery state of charge: 3 - 5% . Victron Multiplus 48/3000/35 ≥ 2 ≥1 ≥ 5 ≥ 2 Multiplus 48/5000/70 ≥ 3 ≥1 ≥ 7 ≥ 2 Multigrid 48/3000/35 ≥ 2 ≥1 ≥ 5 ≥ 2 Quattro 48/ 5000/70 - 100/100 ≥ 3 ≥1 ≥ 7 ≥ 2 Quattro 48/8000/110 - 100/100 ≥ 4 ≥1 ≥1 2 ≥ 3 Quattro 48/10000/140 - 100/100 ≥ 5 ≥ 2 ≥1 5 ≥ 4 Quattro 48/15000/200 - 100/100 ≥ 7 ≥ 2 ≥1 8 ≥ 5 Easysolar 48/3000/35 - 50 MPPT150/70 ≥ 2 ≥1 ≥ 5 ≥ 2 Easysolar 48/5000/70 - 100 MPPT150/100 ≥ 3 ≥1 ≥ 7 ≥ 2 Battery firmware: BMU ≥ V1.16, BMS ≥ V1.8; Inverter firmware ≥ V2.52 Selectronic SPMC480 - AU ≥ 2 ≥1 ≥ 4 ≥1 SPMC481 - AU ≥ 3 ≥1 ≥ 6 ≥ 2 SPMC482 - AU ≥ 5 ≥ 2 ≥ 8 ≥2 Battery firmware: BMU ≥ V1.17, BMS ≥ V1.8; Selectronic SP Link firmware ≥ 14.20.x, SP Pro f irmware ≥ V12.x Studer XTS1400 - 48 ≥1 ≥1 ≥ 2 ≥1 XTM2600 - 48 ≥ 2 ≥1 ≥5 ≥ 2 XTM4000 - 48 ≥ 3 ≥1 ≥ 8 ≥ 2 XTH6000 - 48 ≥ 4 ≥1 ≥1 1 ≥ 3 XTH8000 - 48 ≥ 5 ≥ 2 ≥1 5 ≥ 4 VT - 65 ≥1 ≥1 ≥1 ≥1 V T - 80/ VS - 70 ≥ 2 ≥1 ≥ 2 ≥1 VS - 120 ≥ 3 ≥1 ≥ 3 ≥1 Battery firmware: BMU ≥ V1. 16 , BMS ≥ V1. 8; Inverter firmware ≥ R664 GoodWe ES Series ≥ 2 ≥1 / / GW3048 - EM ≥ 1 ≥1 / / GW3648 - EM / GW 5048 - EM / SBP Series ≥ 2 ≥1 / / Battery firmware: BMU ≥ V1. 16 , BMS ≥ V1. 8; Inverter firmware ≥ ARM V11 Sungrow SH5K - 30 ≥1 ≥1 / / Battery firmware: BMU ≥ V1. 1 6 , BMS ≥ V1. 8; Inverter firmware ≥ SH5K - 30_V01_V004 S olis RHI - 3K / 3.6K - 48ES - 5G ≥1 ≥1 / / RHI - 4.6K / 5K / 6K - 48ES - 5G ≥ 2 ≥1 / / RAI - 3K - 48ES - 5G ≥1 ≥1 / / Battery firmware: BMU ≥ V1.19, BMS ≥ V1.08; Solis RHI (3 - 6K) - 48ES - 5G firmware ≥ V330022, RAI - 3K - 48ES - 5G ≥ V0B0009 Schneider Conext XW Pro ≥ 4 ≥1 Battery firmware: BMU ≥ V1.20, BMS ≥ V1.10; Inverter firmware: Gateway FW :v1.14-BN465, XW FW: 1.10 / /

Weergaven

  • 1324 Totale weergaven
  • 1059 Websiteweergaven
  • 265 Ingesloten weergaven

Acties

  • 0 Gedeeld op sociale media
  • 0 Vind-ik-leuks
  • 0 Vind-ik-niet-leuks
  • 0 Opmerkingen

Aantal malen gedeeld

  • 0 Facebook
  • 0 Twitter
  • 0 LinkedIn
  • 0 Google+

Insluitingen 3

  • 24 www.powergo.pl
  • 6 178.216.200.66
  • 14 178.216.200.66:8069